skip to Main Content

 

Innerglass Window Systems Interior Storm Window Test Results

Glass interior storm windows that outperform almost any replacement, yet maintain the integrity and beauty of your historic windows.

Bid Specifications   Air Infiltration   Noise Reduction

Air Infiltration:

Tested by Thompson & Lichtner – Engineering and Testing

Brooksby Village Interior Storm Windows

December 2010 – Brooksby Village Project

ASTM E 783: Standard Method for Field Measurement of Air Leakage through installed Exterior Windows and Doors

Air infiltration with 25 mph wind pressure at 1.57 psi

Measured: .04 cfm /per square foot

Test standard: .30 cfm/per square foot 7.5 times tighter than the test standard!

Tighter than almost any replacement window costing 3 times as much!


Noise Reduction:

Tested by Intertek Testing Services June 1997Soundproof Interior Storm Windows

ASTM E90-90 Sound transmission loss test

Sound transmission class was determined to be STC 27

A further test was done by hermetically sealing around the edges with “Dux-Seal” which only raised it to STC 28, showing that our seals are extremely good. This test qualified us to supply windows to the Boston Central Artery Project for soundproofing around their construction sites.